Selection GuideWorkshop & machinery15 min read

PTFE vs FEP vs PFA Tubing: 200 °C or 260 °C, Clear or Opaque, and an Eightfold Price Gap

All three tubes look alike on a bench. Curbell sets relative cost at 1 for PTFE, 8 for FEP and 12 for PFA, and the temperature ceilings differ by 56 °C.

Updated November 13, 2026How Equipvia researches
Coils of clear fluoropolymer tubing photographed on a bench, showing the transparency of the material
One of the three is opaque and two are clear, and that difference alone decides some purchases. Photograph via Wikimedia Commons (CC BY-SA 3.0). View image source.

Disclosure: We may earn a commission if you purchase through links on this page, at no additional cost to you. Our selection criteria do not depend on commission; see our affiliate disclosure.

Curbell Plastics lists continuous service temperature as 500 °F for PTFE and PFA and 400 °F for FEP, which is 260 °C against about 204 °C. The same table sets relative cost at 1 for PTFE, 8 for FEP and 12 for PFA. Three tubes that look alike on a bench therefore differ by a factor of twelve in material price and by 56 °C in temperature ceiling, and two of them are see-through while one is not.

What the numbers look like side by side

Curbell's table gives tensile strength per ASTM D638 as 3,600 psi for PFA, 4,350 for FEP and 3,500 for PTFE. Elongation is 300, 313 and 300 percent. Flexural modulus per ASTM D790 is 85, 95 and 100 kpsi. Continuous service is 500, 400 and 500 °F. Relative cost is 12, 8 and 1. Curbell's own caption says the three perfluorinated materials have low strength and low modulus, which is why they work as flexible tubing, and its note adds that properties vary with grade and processing.

Property (Curbell table) PTFE FEP PFA
Tensile strength, ASTM D638 3,500 psi 4,350 psi 3,600 psi
Flexural modulus, ASTM D790 100 kpsi 95 kpsi 85 kpsi
Continuous service 500 °F (260 °C) 400 °F (204 °C) 500 °F (260 °C)
Relative cost (PTFE = 1) 1 8 12

Expressed in metric, 3,500 psi is 24.1 MPa, 3,600 psi is 24.8 MPa and 4,350 psi is 30.0 MPa at 6.895 kPa per psi, while the moduli of 100, 95 and 85 kpsi are about 689, 655 and 586 MPa. Fluorocarbon's reference page gives a coefficient of friction of 0.03 to 0.05 for PTFE and a dielectric strength of 50 to 100 kV/mm. For a lab bench, neither number decides much. Temperature, visibility and cost do.

Where the sources disagree

Three conflicts matter for a purchase, and they do not resolve cleanly.

Transparency. Koto says PFA combines the optical transparency of FEP with the thermal rating of PTFE. KINTEK's FAQ says FEP is generally clearer than PFA and rates PFA clarity as moderate against high for FEP. Both can be true if the comparison is between particular grades, but a buyer who needs to see a bubble front should ask for a sample length of the exact grade before ordering a coil.

FEP temperature. Fluorocarbon says about 200 °C, Darwin 205 °C, Besteflon and KINTEK 200 °C, Curbell 400 °F, which converts to 204 °C. Those are close enough to treat as one figure, but planning to 180 °C for continuous use is the safer habit. That margin is judgment, not published.

Cost. KINTEK lists processing cost as lower for FEP and higher for PTFE and PFA. Curbell lists material cost at 1 for PTFE, 8 for FEP and 12 for PFA. The two tables measure different things, and how KINTEK scored its cost row is not stated. If a length of PTFE tubing cost 10 units, Curbell's multiples would put the same material mass of FEP at 80 and PFA at 120. Real quotes reflect wall, length and vendor, so the multiples show how far apart material prices can sit and do not predict a quote.

Temperature again. Teflon's technical page lists the wire ratings behind the tubing numbers: appliance wire at 200 °C for FEP and 250 °C for PFA and PTFE, and CSA C22.2 No. 127 equipment lead wire at 250 °C for PFA and PTFE and 200 °C for FEP. Those electrical ratings sit 10 °C under the 260 °C that Curbell, Koto and Fluorocarbon quote for continuous service and agree with the 200 °C for FEP, which shows that a temperature ceiling depends on the test it comes from.

Chemical resistance and gas permeation

Fluorocarbon calls all three highly resistant and puts PTFE and PFA slightly ahead, while Besteflon rates FEP as good and says some solvents are slightly inferior, and neither names the solvents. Curbell's water vapour row reads 5 for PTFE, 8 for PFA and 1 for FEP in g/m²·day·bar; its air and oxygen rows carry six values for seven columns and are not quoted here. Fluorocarbon credits PFA with better permeation resistance than PTFE. Koto says Junkosha sells a high-barrier PFA grade for atmospheric gases and extractables. Darwin and Zeus both give FEP "better gas and vapour permeability properties", without saying lower or higher.

Where dissolved oxygen is the failure mode, ask for a measured permeation value for the exact wall and diameter. That is judgment, but it follows from how loosely the sources describe the property.

Which standard covers which tube

ASTM D3295 splits PTFE tubing into five groups: AWG sizes, fractional inch sizes, inner diameter with wall, spiral cut and miniature beading, with wall classes from 1 (light) to 5 (heavy), class 4 labelled chemical tubing, and it requires tests for melting point, specific gravity, weight loss, tensile strength, elongation, dielectric breakdown voltage, heat resistance and dimensional stability.

The Teflon technical page lists D3296 for FEP tubing, D2116 for FEP moulding and extrusion materials and D3307 for PFA moulding and extrusion materials, while an ANSI listing also shows a separate ASTM specification for PFA tubing. The same page lists SEMI C90 for testing PFA in liquid chemical distribution and SEMI F57 for polymer materials in ultrapure water and chemical systems. None of these rates chemical resistance, so a tube sold as "meets ASTM D3295, class 4" is a PTFE tube of chemical-tubing wall and nothing more. Besteflon, a seller, excludes FEP above 200 °C, sends transparency or welding to PFA, sends low-cost transparency with flexibility to FEP, and calls PTFE cheapest where only heat and inertness matter.

ASTM D3295 has appeared in editions dated 1997, 2006, 2011 (as 06R11), 2015 and 2020. The 1997 edition is titled Specification for PTFE Tubing and says no ISO standard exists on the subject; from 2006 the title adds miniature beading and spiral cut tubing, and the 2020 edition notes that it and ISO 13000-1 and -2 address some of the same subject matter but differ in technical content. ASTM's store lists D3295-20, the current edition, at $72.

What the vendors claim for each material

Fluorocarbon's bullet lists give PTFE a friction coefficient of 0.03 to 0.05, dielectric strength of 50 to 100 kV/mm, high elongation and cryogenic performance; PFA melt-processability, improved creep resistance compared with PTFE and lower void content; and FEP dielectric strength of about 55 kV/mm, transparency in many grades and flexibility down to about −200 °C. Its uses for FEP include aerospace and industrial wire and cable insulation, transparent chemical tubing, liners and coatings, cryogenic seals and medical and laboratory components; PTFE appears in static sealing, and PFA is preferred where purity and low permeability are critical, as in semiconductor and hydrogen systems.

KINTEK's comparison table gives FEP "High" optical clarity, PTFE "Low" and PFA "Moderate", melt-processable yes, no and yes, and UV and weather resistance excellent, good and good. Koto adds that Junkosha's peelable heat-shrink ITP-01 is FEP because its lower processing temperature and melt-flowable behaviour allow clean peel-away, and that FEP shrink tubing lets operators see device placement during catheter reflow.

Curbell sums the three up in one line each: PTFE has excellent release characteristics; FEP combines low strength and stiffness, ideal for flexible tubing in high purity fluid handling, with a lower service temperature and lower cost than PFA; PFA offers the same flexibility with a higher service temperature and higher cost than FEP.

Choosing by the job

Above 200 °C continuous, use PTFE or PFA. To see the fluid, FEP is the cheaper clear option. For a heated line that must be both clear and above 200 °C, only PFA fits. Where budget dominates, PTFE sits at one-eighth to one-twelfth of Curbell's relative cost, remembering that tubing price also reflects wall, length and vendor. Above low-pressure bench work, look at PEEK, since Darwin says the soft fluoropolymers are mainly used at low pressure.

Darwin's guide lists PEEK as having one of the highest strength-to-weight ratios of all thermoplastics, usable at low and high pressure, inert to most solvents, with a smooth internal surface; ETFE as stiffer than PTFE, FEP and PFA; and PFA with water absorption under 0.01 percent. It says tubing choice is mainly set by chemical compatibility with the fluids, then by pressure and compatibility with the rest of the set-up.

Equipvia may earn a commission from qualifying purchases through this link. The link resolved to Product ID 1601195372439 during review. CPS resolution does not verify the seller's technical claims, the polymer, affiliate eligibility, or commission attribution. Check the actual selected variant and current terms before ordering.

This listing is a good example of why the polymer has to be written on the order. It carries both PFA and FEP in one title, so the material can depend on which size you click, and the two differ by about 56 °C of continuous rating and by a factor of roughly 1.5 in Curbell's cost multiples. Ask which polymer each inner diameter is extruded from, the continuous service temperature for that grade, the pressure rating at your working temperature, and whether the coil is one continuous length, since a joint in a chemical line is a leak waiting to happen.

Cold lines, and the partially fluorinated relatives

Fluorocarbon says PTFE performs outstandingly at cryogenic temperatures and FEP stays flexible to about −200 °C, and Darwin gives −190 °C for FEP and −200 °C for PFA. Curbell's table adds the partially fluorinated relatives: ETFE at 6,700 psi tensile, 170 kpsi flexural modulus, 300 °F (about 149 °C) and relative cost 14; PVDF at 261 °F (about 127 °C) and cost 2; PCTFE at 380 °F (about 193 °C) and cost 17; ECTFE at 300 °F and cost 6.

In metric, Curbell's partially fluorinated rows read ETFE 46.2 MPa tensile and 1,172 MPa flexural modulus at 300 % elongation; PVDF 41.4 MPa, 1,345 MPa and 65 %; PCTFE 36.5 MPa, 1,551 MPa and 175 %; ECTFE 31.0 MPa, 1,689 MPa and 255 %. Against the 24.1 to 30.0 MPa and 586 to 689 MPa of the three tubing polymers, ETFE is about 1.5 times as strong as FEP and about 1.7 times as stiff as PTFE, and PVDF is the cheapest of the group at a relative cost of 2. Darwin says ETFE is stiffer than the other three, so the tube resists collapse, and less permeable to gases.

What to write on the order

The ASTM groups give three ordering systems for one product — AWG sizes, fractional inch sizes, and inner diameter with wall thickness — so a quote that says "1/8 inch" without inner or outer diameter or a wall class fits three different tubes. The purchase order should carry inner diameter, outer diameter, wall class or thickness, material, length and grade, and an extractables statement if the tube touches an analytical sample. Write the units on the order too, since millimetres and inches both appear on vendor pages. Darwin's guide says low internal volume and fitting compatibility often decide microfluidic choices before chemistry does, and Curbell lists low leaching and low outgassing among fluoropolymer benefits without a number.

Size conversions that come up in quotes: 1 inch is 25.4 mm, so 1/8 inch is 3.175 mm and 1/4 inch is 6.35 mm, and a tube with a 1/8 inch outer diameter and a 1/16 inch (1.5875 mm) bore leaves a wall of 1/32 inch, or 0.79 mm.

What this article could not check

ASTM D3295, D3296 and D3307 were read only as store abstracts, D3295-20 being $72. Curbell's air and oxygen rows carry six values for seven columns and are not quoted. No comparison of PFA against FEP clarity at equal wall was found. The 1, 8 and 12 cost multiples come from one distributor and cover material only. The 180 °C margin for continuous FEP use is a recommendation, not a published figure.

Share this article

View all guides