Equipment Hub / Fertigation & dosing

Fertigation, Dosing Pump and Drip Irrigation Guides

Injectors, dosing pumps, stock tanks, filtration, backflow protection and the sensors that control them.

Parts covered: Diaphragm and valve kits, injectors, filters, suction tubing, relief valves, flow meters, EC and pH probes.

Choose the right part

Selection and fit guides

Selection Guides·14 min read

How to Match a Replacement Diaphragm to a Chemical Metering Pump

A torn diaphragm interrupts dosing, but the first PTFE part that looks right is not a match. This guide covers identity codes, diaphragm versus kit, the layered construction behind a PTFE label, and receipt inspection.

Updated October 20, 2026
Selection Guides·14 min read

Guide to Sizing a Calibration Column for a Fertilizer Dosing Pump

A column is sized by the volume the pump withdraws during a useful test, not by its printed capacity. This guide converts flow and test time into required drawdown, then checks whether the low end stays readable.

Updated October 19, 2026
Selection Guides·14 min read

Where Should an EC Sensor Go in a Fertigation System?

An EC probe measures the liquid around its electrodes, not the recipe on the controller screen. This guide maps the four measurement points, explains why the control probe belongs after injection and mixing, and turns placement into an RFQ and commissioning test.

Updated October 17, 2026
Selection Guides·15 min read

Should a Fertigation Stock Tank Be Opaque?

Opaque and covered is the practical default for stock solution. This guide separates wall colour from real opacity, maps the light paths to check and lists the tests and RFQ wording that prevent a vague tank quote.

Updated October 16, 2026
Selection Guides·15 min read

What Vent Does a Fertigation Stock Tank Need?

A stock tank needs a deliberate air path whenever liquid moves in or out. This guide separates the vent from the overflow, sizes the airflow case and gives a water-only commissioning test.

Updated October 16, 2026
Comparisons·16 min read

Which Material Should a Fertigation Stock Tank Use?

There is no universal best tank material. This guide screens the main options, lists the five variables that change the answer, and shows what a delivered-variant check must confirm.

Updated October 16, 2026
Selection Guides·16 min read

How Much Secondary Containment Does a Fertigation Tank Need?

There is no universal 110 percent rule. This guide runs the screening arithmetic for one tank, A/B pairs and transfer pads, then lists the checks that decide whether a spill pallet actually complies.

Updated October 16, 2026
Selection Guides·16 min read

What Mesh Filter Do You Need After Fertilizer Injection?

Mesh is a label, not a specification. This guide converts a mesh number into a usable aperture, sets the filtration boundary and shows what to verify before a fertigation filter is approved.

Updated October 15, 2026
Selection Guides·15 min read

How Big Should a Fertigation Stock Tank Be?

Tank volume follows stock draw, not nominal capacity. This guide calculates working volume, checks solubility and refill interval, and lists what a quote must document.

Updated October 15, 2026
Selection Guides·15 min read

Which Backflow Device Fits a Drip Fertigation System?

A check valve, atmospheric vacuum breaker, pressure vacuum breaker, reduced-pressure assembly, and chemigation arrangement do not provide the same protection. This guide maps the device role to the fertigation risk before purchase.

Updated October 12, 2026

System design

System and technical guides

Selection Guides·14 min read

One Injector or One Per Zone? Choosing a Fertilizer Dosing Layout

One injector can serve several zones, but only when the hydraulic path, recipe schedule and operating range agree. This guide turns the layout decision into a zone register, a comparison table and an acceptance test before you buy equipment.

Updated October 18, 2026
Selection Guides·15 min read

How to Wire a 4–20 mA or RS485 pH Sensor to a Fertigation Controller

A pH value on the screen is not proof that the loop is correct. This guide treats electrode, transmitter, controller scaling, relay outputs and dosing interlocks as one signal path, and gives a bench-to-production test sequence.

Updated October 17, 2026
Selection Guides·14 min read

How Many Flow Meters Does a Multi-Zone Fertigation System Need?

One meter per valve is not automatically right, and neither is one meter for the whole farm. This guide maps shared, branch and hybrid layouts to the decisions they can actually support, and shows how simultaneous zones change the answer.

Updated October 17, 2026
Selection Guides·15 min read

Does a Fertigation Stock Tank Need a Bottom Drain?

A bottom drain is a cleanout decision, not a decoration. This guide covers when it earns its place, how to choose the low point and valve, and how to test the drain before it enters service.

Updated October 16, 2026
Selection Guides·16 min read

Why Do Fertigation Systems Use A and B Tanks?

A and B are not marketing labels. This guide maps which concentrates must stay apart, how the two liquid paths should meet, when a third tank is justified and what a dosing quote must document.

Updated October 15, 2026
Selection Guides·17 min read

Is Your Fertilizer Injector Really Dosing at 1:100?

A field calibration and acceptance guide for checking whether a fertigation injector actually delivers a 1:100 ratio under the pressure, flow and stock conditions of the installed zone.

Updated October 13, 2026
Selection Guides·14 min read

Do Drip Irrigation Zones Need Air Relief Valves?

Air relief is a hydraulic-event decision, not a universal drip-irrigation accessory. This guide separates air release, vacuum admission, placement, sizing, and field commissioning before purchase.

Updated October 12, 2026
Troubleshooting·15 min read

How Long Should You Flush a Drip Fertigation System?

Flush time is measured rather than copied. This field method uses travel time, endpoint concentration, clean-water baseline, and zone conditions to set a repeatable fertigation flush value.

Updated October 12, 2026

When something is wrong

Troubleshooting

Troubleshooting·15 min read

When Should You Clean or Replace a Fertilizer Injection Valve?

A blocked tip is only one reason a dosing line stops delivering. This guide separates residue that can be flushed from a check assembly that has failed, then defines the evidence needed to clean, replace or stop and investigate.

Updated October 20, 2026
Troubleshooting·15 min read

How to Prime a Fertilizer Dosing Pump and Keep It Primed

If a fertilizer pump needs priming every morning, the job is not finished. This guide covers the approved bleed path, the first-dose test after a realistic idle, and what to measure before replacing valves or pump heads.

Updated October 19, 2026
Troubleshooting·14 min read

Why Does Fertilizer Keep Flowing After the Dosing Pump Stops?

A pump can stop electrically while liquid keeps moving hydraulically. This guide separates a short discharge tail from continuing tank depletion, shows how to test the shutdown state safely, and turns the fix into a specified valve function rather than the word anti-siphon.

Updated October 18, 2026
Troubleshooting·15 min read

Why Does a Fertigation pH Probe Drift?

A drifting pH value is usually a measurement-system problem before it is a crop problem. This guide separates the five failure modes, gives a repeatable service sequence, and turns the replace-or-repair decision into written acceptance criteria.

Updated October 17, 2026

Other categories